Results for category "18x20"

3 Articles
18x20-Water-to-Air-Heat-Exchanger-1Copper-Ports-With-Install-Kit-01-fxt

18×20 Water to Air Heat Exchanger 1Copper Ports With Install Kit

18x20 Water to Air Heat Exchanger 1Copper Ports With Install Kit
18x20 Water to Air Heat Exchanger 1Copper Ports With Install Kit
18x20 Water to Air Heat Exchanger 1Copper Ports With Install Kit
18x20 Water to Air Heat Exchanger 1Copper Ports With Install Kit
18x20 Water to Air Heat Exchanger 1Copper Ports With Install Kit
18x20 Water to Air Heat Exchanger 1Copper Ports With Install Kit
18x20 Water to Air Heat Exchanger 1Copper Ports With Install Kit
18x20 Water to Air Heat Exchanger 1Copper Ports With Install Kit
18x20 Water to Air Heat Exchanger 1Copper Ports With Install Kit
18x20 Water to Air Heat Exchanger 1Copper Ports With Install Kit
18x20 Water to Air Heat Exchanger 1Copper Ports With Install Kit

18x20 Water to Air Heat Exchanger 1Copper Ports With Install Kit
18X20 / 144,000 BTUs / 100 PSI For use in your hot air furnace plenum. Please see charts in pics above. Not recommended for air compressors. This listing includes the install kit. Information about our heat exchangers. This heat exchanger is ideal for a 18″x21″ plenum or larger. The outlets come out on the 18 side (shown as the vertical side in the picture above). The fin area is 18″x20″. Outside Dimensions 18(width)x23.5(Length from Manifold to Base)x3.5(Thickness). There is a 1 frame on the end opposite the outlets that covers the copper elbows. This makes the area inside of your plenum 1 longer. All exchangers are 3 1/2 thick. Aluminum fins are installed at 12 fines per inch. All exchangers are triple pass design. Tubing is 1/4 copper. All our exchangers include the flat front face mounting for easier installation and increased plenum strength. Our exchangers have 1 copper outlets and can be installed with either sweat fittings or push fit type fittings like sharkbite’s. Exchangers will work with chilled water also. We stock many sizes, always order the largest size that will fit into your plenum. This also includes the installation kit shown in the pictures above. Installation brackets for installing water to air heat exchangers inside of furnace plenums. This easy to install kit takes all of the work out of installing a coil. Great for the do it yourselfer or the seasoned installer. Even most that are listed as 4″ are actually 3.5″. These heat exchangers are to be hooked up to a boiler or a chilled water source. These heat exchangers can also be used as a stand alone heat source by simply attaching a fan or squirrel cage to one side of the unit. They can be installed in either the hot air side or the cold air return of a furnace. Please note that if installed in the cold air return you will need to install a 3 way zone valve in order for the fan to operate properly. This heat exchanger is of a new style which does not require bending of your duct work. This new style heat exchanger can be easily installed by just slipping it into the plenum and attaching with self threading screws. You will not need any special tools to install. This unit is easier to install than others on the market because it attaches from the front instead of the side. Water to Air heat exchangers, often called duct coils or furnace radiators, are used for installing into forced air furnace to provide heat from hot water. They are usually installed into the cold air side of the furance if that is the best option. They work in much the same way as the central air conditioning unit. The following things should be taken into consideration when installing a duct coil. (1) Size the coil so that the fins take up the maximum amount of the plenum as possible. (2) Securely fasten the unit so that it doesn’t rattle. (3) Make sure there are no foreign objects are touching the fins or the tubes. (4) Duct tape any air leaks. (5) Do not bend the fins. If you do, straighten them as best you can. A tool called a “Rake” is available for straightening the fins. (6) If you are going to run your outside heat in the summer install a bypass valve. (7) A duct coil installation kit makes installing the heat exchanger easier. The item “18×20 Water to Air Heat Exchanger 1Copper Ports With Install Kit” is in sale since Thursday, December 26, 2019. This item is in the category “Business & Industrial\HVAC & Refrigeration\HVAC & Refrigeration Components\Heat Exchangers”. The seller is “badger-pipe” and is located in Mauston, Wisconsin. This item can be shipped worldwide.
  • Brand: Undisclosed
  • MPN: Does not apply

18x20 Water to Air Heat Exchanger 1Copper Ports With Install Kit
18x20-Water-to-Air-Heat-Exchange-1-Copper-Ports-with-EZ-Install-Front-Flange-01-xcj

18×20 Water to Air Heat Exchange 1 Copper Ports with EZ Install Front Flange

18x20 Water to Air Heat Exchange 1 Copper Ports with EZ Install Front Flange
18x20 Water to Air Heat Exchange 1 Copper Ports with EZ Install Front Flange

18x20 Water to Air Heat Exchange 1 Copper Ports with EZ Install Front Flange
18×20 / 144,000 BTUs / 100 PSI. For use in your hot air furnace plenum. Not recommended for air compressors. Information about our heat exchangers. This heat exchanger is ideal for a 18″x 21″ plenum or larger. The outlets come out on the 18 side (shown as the vertical side in the picture above). The fin area is 18″x 20″. Outside Dimensions 18(width)x23.5(Length from Manifold to Base)x3.5(Thickness). There is a 1 frame on the end opposite the outlets that covers the copper elbows. This makes the area inside of your plenum 1 longer. All exchangers are 3 1/2 thick. Aluminum fins are installed at 12 fines per inch. All exchangers are triple pass design. Tubing is 1/4 copper. All our exchangers include the flat front face mounting for easier installation and increased plenum strength. Our exchangers have 1 copper outlets and can be installed with either sweat fittings or push fit type fittings like sharkbite’s. Exchangers will work with chilled water also. We stock many sizes, always order the largest size that will fit into your plenum. This easy to install kit takes all of the work out of installing a coil. Great for the do it yourselfer or the seasoned installer. Even most that are listed as 4″ are actually 3.5″. These heat exchangers are to be hooked up to a boiler or a chilled water source. When hooked up to your boiler or chilled water source, these heat exchangers can also be used as a stand alone heat source by simply attaching a fan or squirrel cage to one side of the unit. They can be installed in either the hot air side or the cold air return of a furnace. Please note that if installed in the cold air return you will need to install a 3 way zone valve in order for the fan to operate properly. This heat exchanger is of a new style which does not require bending of your duct work. This new style heat exchanger can be easily installed by just slipping it into the plenum and attaching with self threading screws. You will not need any special tools to install. This unit is easier to install than others on the market because it attaches from the front instead of the side. Water to Air heat exchangers, often called duct coils or furnace radiators, are used for installing into forced air furnace to provide heat from hot water. They work in much the same way as the central air conditioning unit. The following things should be taken into consideration when installing a duct coil. (1) Size the coil so that the fins take up the maximum amount of the plenum as possible. (2) Securely fasten the unit so that it doesn’t rattle. (3) Make sure there are no foreign objects are touching the fins or the tubes. (4) Duct tape any air leaks. (5) Do not bend the fins. If you do, straighten them as best you can. A tool called a “Rake” is available for straightening the fins. (6) If you are going to run your outside heat in the summer install a bypass valve. (7) A duct coil installation kit makes installing the heat exchanger easier. The item “18×20 Water to Air Heat Exchange 1 Copper Ports with EZ Install Front Flange” is in sale since Tuesday, July 9, 2019. This item is in the category “Business & Industrial\HVAC & Refrigeration\HVAC & Refrigeration Components\Heat Exchangers”. The seller is “badger-pipe” and is located in Mauston, Wisconsin. This item can be shipped worldwide.
  • Brand: Badger Insulated pipe
  • MPN: Does not apply
  • UPC: 689807252388

18x20 Water to Air Heat Exchange 1 Copper Ports with EZ Install Front Flange
18x20-Water-to-Air-Heat-Exchanger-Hot-Water-Coil-Outdoor-Wood-Furnace-01-tqpi

18×20 Water to Air Heat Exchanger Hot Water Coil Outdoor Wood Furnace

18x20 Water to Air Heat Exchanger Hot Water Coil Outdoor Wood Furnace
18x20 Water to Air Heat Exchanger Hot Water Coil Outdoor Wood Furnace

18x20 Water to Air Heat Exchanger Hot Water Coil Outdoor Wood Furnace
18×20 Water to Air Heat Exchanger Hot Water Coil Outdoor Wood Furnace. This unit is a Water to Air Heat Exchanger for use in your hot air plenum of your existing forced air furnace. This unit is most commonly used in conjuction with an outside wood furnace to transfer heat into your existing forced air system. It can also be used with any other source of hot water such as a boiler to create hot air. This exchanger is for use with ANY outdoor wood stove. And also features quality aluminum fins with seamless copper tubes. The coils fit snuggly in the boxes to minimize movement within the box. There are strips of styrofoam all the way around the manifold to prevent damage if dropped. The entire coil is packaged in a double wall, cardboard box. 15 GPM and 2000 CFM (air flow). Make sure all of your auctions have ended prior to checking out. (Excludes Insulated Piping Systems, please see below). If an item arrives damaged or defective, return it within 7 days of arrival and we will replace it at our expense. The item “18×20 Water to Air Heat Exchanger Hot Water Coil Outdoor Wood Furnace” is in sale since Tuesday, May 17, 2016. This item is in the category “Home & Garden\Home Improvement\Heating, Cooling & Air\Air Conditioners & Heaters\Furnaces & Central Heating Systems”. The seller is “alternativeheat” and is located in Middleport, New York. This item can be shipped worldwide.
  • Brand: Outdoor Furnace Supply
  • Heating System: Furnace
  • Recommended Environment: Outdoor
  • Custom Bundle: No
  • MPN: HWC-18X20

18x20 Water to Air Heat Exchanger Hot Water Coil Outdoor Wood Furnace